Work a CT problem with or without a baffling factor, or convert between pipe flow and velocity using Q = A × V.

CT calculator

CT = Residual (mg/L) × T10 (min), and T10 = Theoretical DT × BF. Leave baffling factor blank or set it to 1.0 if T10 is already given.

Typical textbook factors range from about 0.1 (mixed) to 1.0 (plug flow). Use the factor given in the problem.

Example 1 — CT with a baffling factor

A contact basin has a theoretical detention time of 40 minutes and a baffling factor of 0.5. If the free chlorine residual is 1.2 mg/L, what is the CT?

  1. T10 = 40 × 0.5 = 20 min
  2. CT = 1.2 mg/L × 20 min = 24.0 mg·min/L

Using theoretical detention time in place of T10 (skipping the baffling factor) is a common miss.

Example 2 — Lower residual, longer basin

A clearwell has a theoretical detention time of 90 minutes and a baffling factor of 0.3. The free chlorine residual is 0.80 mg/L. What is the CT?

  1. T10 = 90 × 0.3 = 27 min
  2. CT = 0.80 × 27 = 21.6 mg·min/L

Example 3 — Velocity in a 12-inch main

A 12-inch distribution main carries 800 gpm. What is the flow velocity? Use 0.785 for the area factor.

  1. D = 12 ÷ 12 = 1.00 ft
  2. A = 0.785 × 1.00² = 0.785 ft²
  3. Q = 800 ÷ 448.8 = 1.7825 cfs
  4. V = 1.7825 ÷ 0.785 = 2.27 ft/s

Example 4 — Flow from velocity in a 10-inch pipe

Water is moving at 3.0 ft/s in a 10-inch pipe. What is the flow in gpm and MGD? Use 0.785.

  1. D = 10 ÷ 12 = 0.8333 ft
  2. A = 0.785 × (0.8333)² = 0.54514 ft²
  3. Q = 0.54514 × 3.0 = 1.6354 cfs
  4. GPM = 1.6354 × 448.8 = 733.975 gpm → 734.0 gpm
  5. MGD = 733.975 × 1,440 ÷ 1,000,000 = 1.057 MGD

Keep T10 and pipe diameter units straight

CT uses minutes of T10, not hours of theoretical detention time, unless the problem has already converted them. Pipe problems almost always give diameter in inches; the 0.785 factor needs feet, so divide by 12 first. Leaving the diameter in inches produces an area that is 144 times too large and a velocity that is much too small.

Related: chlorine dosage, detention time, filter backwash & filtration rate, chemical feed & jar test dosage, and the free 10-question quiz.

Keep practicing

Take the free quiz, download the formula sheet, or go deeper with a full study guide

The 10-question quiz, 16 free calculators, and formula quick-reference stay free on this site, with printable PDFs you can download immediately. The $29 Math Workout adds the full 50-problem simulator and workbook. The $39 Class D & C, $39 Small Water System, and $59 Class B & A study guides are printable PDFs plus offline HTML companions, each with a 14-day money-back guarantee. The $79 Colorado Contract ORC Playbook is educational only — not legal, tax, or financial advice, and no income, client, or earnings guarantee, with a 14-day money-back guarantee. The $99 Small System + Contract ORC Bundle combines the $39 study guide and $79 playbook as one digital download, with the same educational-only and 14-day money-back terms. Passing a certification exam is not guaranteed.